Linear Endobronchial Ultrasound Learning CurveLinear Endobronchial Ultrasound Learning Curve: Hard to Predict FREE TO VIEW

Andrew R. L. Medford, MBChB, MD, FCCP
Author and Funding Information

From North Bristol Lung Centre and University of Bristol, Southmead Hospital.

CORRESPONDENCE TO: Andrew R. L. Medford, MBChB, MD, FCCP, North Bristol Lung Centre and University of Bristol, Southmead Hospital, Westbury-on-Trym, Bristol, BS10 5NB, England; e-mail: andrewmedford@hotmail.com


FINANCIAL/NONFINANCIAL DISCLOSURES: The author has reported to CHEST that no potential conflicts of interest exist with any companies/organizations whose products or services may be discussed in this article.

Reproduction of this article is prohibited without written permission from the American College of Chest Physicians. See online for more details.


Chest. 2014;146(6):e221. doi:10.1378/chest.14-0786
Text Size: A A A
Published online
To the Editor:

In their recent article in CHEST (March 2014), Wahidi et al1 reported on the impressively short learning curve for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) among pulmonary trainees who needed only 13 procedures to achieve independent competence. This study clearly demonstrates the usefulness of a standardized EBUS-TBNA lecture from trainers with expertise and also the value of an endobronchial ultrasound simulator/plastic model. It would be interesting to know if the authors have evaluated the specific value of the didactic lecture and the simulator model separately to see the relative value of each component, which may inform curriculum planners.

The situation is more complex regarding the number of procedures required before competency as an independent EBUS-TBNA bronchoscopist. First, an acceptable standard has yet to be clarified or standardized universally among studies, but it is clear from many systematic reviews where the expected sensitivity should be for EBUS-TBNA. The ability to independently intubate, locate, and sample the lymph node/target with adequate samples is obviously a key part of it but does not necessarily equate to the longer-term achievement of adequate diagnostic sensitivity and accuracy after a sustained period of time. Other studies have noted that performance is idiosyncratic and unpredictable even among experienced bronchoscopists2 and that the diagnostic accuracy appears to improve well beyond 100 procedures.3,4 The more debatable point is whether the latter is of clinical significance in defining “competence.” The actual number of procedures for each trainee are not given in the study by Wahidi et al1 but are reported as percentages from a 2-year period; it would be interesting to see the actual numbers.

Second, other variables may impact the learning curve. The mean lymph node size was 1.99 cm in the study by Wahidi et al1 and only 3% of procedures were for staging, implying that the vast majority were for the diagnosis of presumably larger nodes because the mean was just below 2 cm. The learning curve for staging EBUS-TBNA is likely to be a lot longer because the requirement to systematically sample adequately normal-sized lymph nodes, which may be as small as 5 mm, is a different challenge than sampling 2-cm nodes. Rapid on-site evaluation for cytology (ROSE) may have had a positive impact on shortening the learning time by providing immediate feedback, so studies comparing with/without ROSE would be welcome.

In summary, Wahidi et al1 provide interesting data, but further studies on the EBUS-TBNA learning curve are needed to evaluate specifically the learning curve for EBUS-TBNA to an agreed standard over a prolonged period, also taking into account setup variables such as operator competence (preexisting conventional bronchoscopic ability and experience), indication for EBUS-TBNA (lung cancer staging vs diagnosis, size of nodes), pathology (presence/absence of ROSE, processing as cytopathology or histopathology samples5), and education (presence/absence of simulator and didactic lecture).

References

Wahidi MM, Hulett C, Pastis N, et al. Learning experience of linear endobronchial ultrasound among pulmonary trainees. Chest. 2014;145(3):574-578. [CrossRef] [PubMed]
 
Kemp SV, El Batrawy SH, Harrison RN, et al. Learning curves for endobronchial ultrasound using cusum analysis [published corrections appear inThorax. 2010;65(9):844,Thorax. 2012;67(1):84, andThorax. 2014;69(7):672]. Thorax. 2010;65(6):534-538. [CrossRef] [PubMed]
 
Medford ARL. Learning curve for endobronchial ultrasound-guided transbronchial needle aspiration. Chest. 2012;141(6):1643. [CrossRef] [PubMed]
 
Fernández-Villar A, Leiro-Fernández V, Botana-Rial M, Represas-Represas C, Núñez-Delgado M. The endobronchial ultrasound-guided transbronchial needle biopsy learning curve for mediastinal and hilar lymph node diagnosis. Chest. 2012;141(1):278-279. [CrossRef] [PubMed]
 
Jeyabalan A, Shelley-Fraser G, Medford AR. Impact of needle gauge on characterization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) histology samples. Respirology. 2014;19(5):735-739. [CrossRef] [PubMed]
 

Figures

Tables

References

Wahidi MM, Hulett C, Pastis N, et al. Learning experience of linear endobronchial ultrasound among pulmonary trainees. Chest. 2014;145(3):574-578. [CrossRef] [PubMed]
 
Kemp SV, El Batrawy SH, Harrison RN, et al. Learning curves for endobronchial ultrasound using cusum analysis [published corrections appear inThorax. 2010;65(9):844,Thorax. 2012;67(1):84, andThorax. 2014;69(7):672]. Thorax. 2010;65(6):534-538. [CrossRef] [PubMed]
 
Medford ARL. Learning curve for endobronchial ultrasound-guided transbronchial needle aspiration. Chest. 2012;141(6):1643. [CrossRef] [PubMed]
 
Fernández-Villar A, Leiro-Fernández V, Botana-Rial M, Represas-Represas C, Núñez-Delgado M. The endobronchial ultrasound-guided transbronchial needle biopsy learning curve for mediastinal and hilar lymph node diagnosis. Chest. 2012;141(1):278-279. [CrossRef] [PubMed]
 
Jeyabalan A, Shelley-Fraser G, Medford AR. Impact of needle gauge on characterization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) histology samples. Respirology. 2014;19(5):735-739. [CrossRef] [PubMed]
 
NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Find Similar Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543