VIBRATION RESPONSE IMAGING (VRI) IS A USEFUL TOOL FOR ASSESSMENT OF OUTCOME AFTER BRONCHOSCOPIC INTERVENTIONS FREE TO VIEW

Heinrich D. Becker, MD*; Merav Gat, MSc
Author and Funding Information

Thoraxklinik at Heidelberg University, Heidelberg, Germany


Chest


Chest. 2007;132(4_MeetingAbstracts):517a. doi:10.1378/chest.132.4_MeetingAbstracts.517a
Text Size: A A A
Published online

Abstract

PURPOSE: Purpose: Interventional procedures are of increasing importance in bronchology. Gold standards (GS) for monitoring intervention outcome (clinic, lung function, x-ray) are insufficient. Thus, neither different methods nor results in different centers can be reliably compared. Vibration response imaging (VRIXP™) device records lung sounds and displays results as a dynamic image and as quantitative lung data (QLD). We explored VRITM technology's QLD as a means for assessing outcome of bronchoscope interventions.

METHODS: In 81 patients, sent for intervention, lung sounds were recorded by the VRIXP™ device. 47 underwent 59 bronchial interventions (dilation, laser treatment, stenting, resection, lavage). For 28 QLD for left/right lung could be calculated before/after the procedure so far. Outcome was classified by GS and VRITM technology as “better”, “same” or “worse.” VRITM technology classification was “better” if DQLD of pathological lung > 5%; “same” if DQLD of total left/right lung < 5%; worse if not “better” or “same.” GS was an aggregation of physical exam, X-ray, dypsnea scale, and/or lung function test.

RESULTS: The over all accuracy rate of VRITM technology in comparison to GS was 82% (23/28). In cases that were ”better“ according to GS, the accuracy rate was 89% (16/18). In cases that were ”same“ according to GS, the accuracy rate was 4/7, and in ”worse“ cases the accuracy rate was 3/3. The accuracy rate for stent intervention was higher (91%=10/11) than for other intervention modalities (76%=13/17).

CONCLUSION: We observed significant changes in the VRITM technology's QLD that were analogous to pre- and post-intervention GS assessment. QLD may serve as a more objective method for evaluating bronchial intervention outcome. This is an ongoing study and more data will be collected for more robust statistics.

CLINICAL IMPLICATIONS: The VRIXP™ technology's QLD has the potential to quantify bronchoscope interventions in a rapid and radiation free manner and can be even applied in severely compromised patients that can not undergo conventional diagnostic procedures before intervention. This can also influence in choosing the best intervention method.

DISCLOSURE: Heinrich Becker, None.

Wednesday, October 24, 2007

12:30 PM - 2:00 PM


Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

CHEST Journal Articles
PubMed Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543