The purpose of the study was to determine the best surrogate for FVC when performing spirometry to detect obstruction or restriction. Volume-time curves from 3,539 participants in the Family Heart Study with acceptable quality test sessions were analyzed. An index of the variability of each timed volume (FEVx) from 1 to 12 s was determined for each subject. The least within-test session variability was seen for forced expired volume in 6 s (FEV6) and forced expired volume in 7 s (for both, mean range was 95 mL). The sensitivity and specificity for detecting obstruction and restriction when substituting the FEV6 for the FVC were then determined before and after allowing for measurement errors of 50 mL (approximately the lower limit of spirometers ability to detect volume). Sensitivity was 76% before the 50-mL error analysis and 95% after. Specificity was 98% before the 50-mL error analysis and 99.5% after. We conclude that use of FEV6 to replace the FVC for spirometry testing will result in improved reproducibility, with no significant loss of sensitivity or specificity, after allowing a 50-mL measurement error, for detecting obstruction or restriction.

Figures in this Article

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Related Content

Customize your page view by dragging & repositioning the boxes below.

CHEST Journal Articles
FEV1 Performance Among Patients With Acute Asthma*: Results From a Multicenter Clinical Trial
Estimating FVC From FEV2 and FEV3*: Assessment of a Surrogate Spirometric Parameter
PubMed Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543