0
Original Research: PULMONARY FUNCTION TESTING |

The Effect of Challenge Method on Sensitivity and Reactivity to Adenosine 5′-Monophosphate in Subjects With Suspected Asthma*

Luis Prieto, MD, PhD; Isabel Reig, MD; Rocio Rojas, RN; Anna Ferrer, MD; Juan Domenech, MD, PhD
Author and Funding Information

*From the Sección de Alergología (Drs. Prieto, Ferrer, and Domenech, and Ms. Rojas), Hospital Universitario Dr. Peset, Valencia, Spain; and Servicio de Alergología (Dr. Reig), Hospital Clínico, Madrid, Spain.

Correspondence to: Luis Prieto, MD, PhD, Sección de Alergología, Hospital Universitario Dr. Peset, C/ Gaspar Aguilar 90, 46017 Valencia, Spain; e-mail: prieto_jes@gva.es



Chest. 2006;130(5):1448-1453. doi:10.1378/chest.130.5.1448
Text Size: A A A
Published online

Background: The following two methods of inhalation challenge have been used to determine the airway responsiveness: the tidal-breathing method; and the dosimeter method. The objective of the study was to determine the influence of the challenge method on the response to adenosine 5′-monophosphate (AMP).

Methods: This study measured airway responsiveness to AMP by dosimeter and tidal-breathing methods in 25 subjects with suspected asthma. The two AMP challenges were conducted in random order, on separate days, at the same time of day, at intervals of 1 to 5 days. Concentration-response curves were characterized by the provocative concentration of a substance causing a 20% fall in FEV1 (PC20) and slope.

Results: The dosimeter PC20 values were significantly higher than the tidal-breathing PC20 values, with geometric mean (95% confidence interval [CI]) values of 50.35 mg/mL (95% CI, 19.50 to 129.72 mg/mL) and 28.97 mg/mL (95% CI, 11.99 to 69.98 mg/mL; p = 0.02), respectively. The mean difference in the PC20 values obtained with each method was 0.80 doubling concentrations (95% CI, 0.16 to 1.44 doubling concentrations). The mean values for the slope were 17.0%/log mg/mL (95% CI, 12.5 to 21.5 mg/mL) with the tidal breathing method and 13.8%/log mg/mL (95% CI, 9.0 to 18.7 mg/mL; p = 0.03) with the dosimeter.

Conclusions: The tidal-breathing method produces AMP PC20 values that are significantly lower than the dosimeter method and slope values that are significantly higher than the dosimeter method. These data suggest that the results obtained with each method of testing may not be comparable.

Figures in this Article

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Related Content

Customize your page view by dragging & repositioning the boxes below.

CHEST Journal Articles
Difference Between Dosimeter and Tidal Breathing Methacholine Challenge*: Contributions of Dose and Deep Inspiration Bronchoprotection
PubMed Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543