Correlation of Leukocyte Esterase Detection by Reagent Strips and the Presence of Neutrophils*: A Study in BAL Fluid

Jan A. Jacobs, MD, PhD; Els I. G. B. De Brauwer, MD; Elisa I. M. Cornelissen, MT; Marjolein Drent, MD, PhD
Author and Funding Information

*From the Departments of Medical Microbiology (Drs. Jacobs, De Brauwer, and Ms. Cornelissen) and Pulmonology (Dr. Drent), University Hospital Maastricht, Maastricht, The Netherlands.

Correspondence to: Jan A. Jacobs, MD, PhD, Department of Medical Microbiology, University Hospital of Maastricht, PO Box 5800, 6202 AZ Maastricht, The Netherlands; e-mail: JJA@ms-azm-3.azm.nl



Chest. 2000;118(5):1450-1454. doi:10.1378/chest.118.5.1450
Text Size: A A A
Published online

Study objective: In the present study, we evaluated the leukocyte esterase (LE) area of a reagent strip designed for urinalysis for the semiquantitative measurement of the percentage of polymorphonuclear neutrophils (PMNs) in BAL fluid.

Design: Prospective. The relative PMN counts (obtained by conventional microscopy and expressed as a percentage of a 500 cell count) of consecutive BAL fluid samples were compared with the corresponding LE categories as read with a urine chemistry reader. LE categories were graded as follows: negative, trace, +, + +, and+ + +.

Results: A total of 153 BAL fluid samples were included. The mean PMN counts of the negative LE category (4.1 ± 4.3%; n = 43) and the + + + category (81.8 ± 16.3%; n = 37) differed significantly from each other and from the mean PMN counts of the other categories. Within the trace, +, and + + categories, a considerable overlap of PMN counts was noted. Assignment of a BAL fluid to the negative LE category consistently predicted a PMN count < 20%. At a threshold value of 50% PMNs, the + + + LE category predicted the BAL fluid samples to the correct group (PMNs> 50% vs < 50%) with a sensitivity of 70.8% and a specificity of 97.1%.

Conclusions: The reagent strips proved to be useful as a rapid test for semiquantitative measurement of the relative PMN counts in BAL fluid. However, the low predictive value for the exclusion of a high PMN count may limit their application.

Figures in this Article

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Find Similar Articles
CHEST Journal Articles
PubMed Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543