Performance of Transport Ventilator With Patient-Triggered Ventilation*

Eriko Miyoshi, MD; Yuji Fujino, MD; Takashi Mashimo, MD; Masaji Nishimura, MD
Author and Funding Information

*From the Intensive Care Unit (Drs. Miyoshi, Fujino, Mashimo, and Nishimura) and Department of Anesthesiology (Dr. Mashimo), Osaka University Hospital, Osaka Japan.

Correspondence to: Yuji Fujino, MD, Intensive Care Unit, Osaka University Hospital, 2–15, Yamadaoka, Suita, Osaka, Japan 565-0871; e-mail: fujino@hp-icu.med.osaka-u.ac.jp



Chest. 2000;118(4):1109-1115. doi:10.1378/chest.118.4.1109
Text Size: A A A
Published online

Objectives: Transport ventilators with inspiratory triggering functions and pressure support–control modes have recently become commercially available. We evaluated these ventilators in comparison with a standard ICU ventilator.

Study design: Laboratory study with a mechanical lung model.

Methods: We compared the performance of four transport ventilators (model 740, Mallinckrodt, Pleasanton, CA; TBird, Bird Products Corp, Palm Springs, CA; LTV1000, Pulmonetic Systems, Colton, CA; Esprit, Respironics, Vista, CA) with a standard ICU ventilator (model 7200ae; Mallinckrodt) using a test lung that simulated spontaneous breathing (compliance, 46.8 mL/cm H2O; resistance, 5 cm H2O/L/s). The settings of ventilators were positive end-expiratory pressure (PEEP) of 0 or 5 cm H2O, and pressure support (PS) of 0 or 10 cm H2O. The settings of the test lung were inspiratory time of 1 s, respiratory rate of 10/min, peak inspiratory flow of 40, 60, and 80 L/min. To evaluate inspiratory function at each setting, we measured the inspiratory delay time (DT), inspiratory trigger pressure (P-I), and the time for airway pressure to rise from the baseline pressure to 90% of the end-inspiratory pressure (T90%); for expiratory function, supraplateau expiratory pressure (P-E) and the time constant (τe) for pressure decrease during exhalation were evaluated. Oxygen requirement was assessed as the time required to empty a 3.5-L oxygen tank.

Results: For inspiratory triggering, four transport ventilators had DT < 100 ms, which is considered clinically satisfactory, in all the settings except for PS 0 cm H2O, PEEP 0 cm H2O, and inspiratory flow of 80 L/min with LTV1000. P-I increased only in LTV1000 when PEEP was increased from 0 to 5 cm H2O. τe for the transport ventilators was> 50% shorter than for the ICU ventilator except for PS 0 cm H2O and PEEP 5 cm H2O with TBird. Oxygen requirement was lowest for the Esprit, followed by the 740, LTV1000, and TBird.

Conclusion: The newer Food and Drug Administration–approved transport ventilators have performance indexes comparable to the ventilator currently used in ICUs and can probably be recommended for clinical use.

Figures in this Article

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Find Similar Articles
CHEST Journal Articles
PubMed Articles
Guidelines
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543