0
Articles |

Pulmonary and Aortic Blood Flow Measurements in Normal Subjects and Patients After Single Lung Transplantation at 0.5 T Using Velocity Encoded Cine MRI

Christine B. Henk; Bernhard Schlechta; Stephan Grampp; Gregor Gomischek; Walter Klepetko; Gerhard H. Mostbeck
Author and Funding Information

Affiliations: From the Department of Radiology, University of Vienna, Vienna, Austria,  From the Department of Ludwig Boltzmann Institute for Physical and Radiological Tumor Diagnosis, The Department of Cardiothoracic Surgery, Vienna, Austria,  From The MR Institute, University of Vienna, Vienna, Austria

Christine B. Henk, MD, Department of Radiology, University of Vienna, Waehringergvertel 18-20 1180, Austria


1998 by the American College of Chest Physicians


Chest. 1998;114(3):771-779. doi:10.1378/chest.114.3.771
Text Size: A A A
Published online

Abstract

Purpose: It is the purpose of this study to compare pulmonary and aortic blood flow measurements obtained in patients after single lung transplantation (SLTX) with those in volunteers.

Methods/material: In nine patients after SLTX (three male, six female) and nine volunteers (seven male, two female), double oblique phase contrast cine-MRI sequences perpendicular to the direction of blood flow were obtained in the ascending aorta, main, right, and left pulmonary artery on a 0.5-T unit (Philips Gyroscan; Best, the Netherlands) (repetition time, 600 to 800 ms; echo time, 8 ms; alpha=30; field of view=280 mm matrix, 128x256, ECG gating, temporal resolution 16 time frames/RR interval). An initial in vitro study using the same sequence on a nonpulsatile flow phantom showed excellent correlation (r=0.99) between MRI measurements of flow velocity and flow volume and true velocity and flow volume. Measurements of blood flow volume (mL/min), peak mean systolic velocity, resistive index, and distensibility index were obtained in each vessel.

Results: We found excellent correlations between left and right cardiac output as measured by velocity encoded cine-MRI (VEC-MRI) in the ascending aorta and main pulmonary artery both in normal volunteers (r=0.95) and in patients (r=0.91). Differential pulmonary blood flow measurements in volunteers showed that 55% of the right cardiac output was directed to the right and 45% to the left lung. Differential pulmonary blood flow in patients showed that most of the blood flow (81%) reaches the transplanted lung and only 19% reaches the patient's own lung (SLTX: 4.5±1.8 L/min, patient's own lung: 1.2±0.8 L/min). There were significant differences (p<0.05) in peak mean systolic velocity and resistive index obtained in the pulmonary arteries, both between normal volunteers and patients and between measurements obtained in the patient's own lung and the transplanted lung.

Conclusion: VEC-MRI blood flow measurements are a promising noninvasive tool to monitor the hemodynamic changes of pulmonary blood flow after SLTX.


Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Find Similar Articles
CHEST Journal Articles
PubMed Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543