0
Articles |

Performance Characteristics of Bilevel Pressure Ventilators : A Lung Model Study

Thananchai Bunburaphong; Hideaki Imanaka; Masaji Nishimura; Dean Hess; Robert M. Kacmarek
Author and Funding Information

From the Respiratory Care Department Laboratory and the Department of Anesthesia, Massachusetts General Hospital and Harvard Medical School, Boston


1997 by the American College of Chest Physicians


Chest. 1997;111(4):1050-1060. doi:10.1378/chest.111.4.1050
Text Size: A A A
Published online

Abstract

Bilevel pressure ventilators are being used increasingly to provide noninvasive ventilatory support in the management of obstructive sleep apnea, chronic ventilatory failure, and acute respiratory failure. However, the ability of these ventilators to respond to inspiratory demand without imposing expiratory loads has not been evaluated extensively. We evaluated the performance of nine bilevel pressure ventilators in a lung model, as compared with the Nellcor Puritan-Bennett 7200ae adult critical care ventilator. All ventilators were set to provide pressure support ventilation (PSV) and positive end-expiratory pressure (PEEP) at a rate of 10 breaths/min with an inspiratory time of 1.0 s. Simulated pleural pressure, airway pressure, and flow at airway opening were continuously monitored. We studied the effects of three PSV levels (5, 10, and 15 cm H2O) with 5 cm H2O PEEP at two lung compliances (50 and 80 mL/cm H2O) and four peak inspiratory flow demands (20, 40, 60, and 80 L/min) on seven dependent variables: inspiratory delay time (D-I), inspiratory trigger pressure (P-I), inspiratory area percent (Area 1%), expiratory delay time (D-E), supraplateau expiratory pressure change (P-E), expiratory area (Area E), and ventilator peak flow (VPF). Most ventilators performed as well as or significantly (p<0.05) better than the 7200ae in all studied variables. Compliance did not significantly affect ventilator performance. Increasing inspiratory flow demand significantly (p<0.05) increased D-I, P-I, P-E, and VPF and decreased Area I% with most ventilators. As ventilatory demand increased, D-E and Area E significantly (p<0.05) changed. With some units, D-E and Area E increased, while with others they decreased. Most bilevel pressure ventilators evaluated were able to respond to high ventilatory demands and outperformed the Nellcor Puritan-Bennett 7200ae ventilator.


Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Figures

Tables

References

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

MEMBER & INDIVIDUAL SUBSCRIBER

Want Access?

NEW TO CHEST?

Become a CHEST member and receive a FREE subscription as a benefit of membership.

Individuals can purchase this article on ScienceDirect.

Individuals can purchase a subscription to the journal.

Individuals can purchase a subscription to the journal or buy individual articles.

Learn more about membership or Purchase a Full Subscription.

INSTITUTIONAL ACCESS

Institutional access is now available through ScienceDirect and can be purchased at myelsevier.com.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Find Similar Articles
CHEST Journal Articles
PubMed Articles
  • CHEST Journal
    Print ISSN: 0012-3692
    Online ISSN: 1931-3543